1. All workshop safety exit doors no longer accept rolling doors or sliding doors; 2. If it is a rolling door or sliding door, a small door needs to be opened on the main door, and the door opens outwards. The door must be painted with fire-retardant paint, and the test report must be retained; or, if factory conditions permit, the door can be directly removed; 3. Rolling doors or sliding doors are not allowed above the second floor (no modification is allowed); 4. Qualified fire doors must be installed on the safety exits above the second floor. They must have push rod locks, door closers, open in the direction of escape, and be at least 1.2 meters wide. A fire door inspection report must be provided, and the fire protection level must reach Class A or Class B. 5. If the distance between two safety exits in a workshop exceeds 61 meters, three safety exits are required; 6. Anti-theft windows cannot be installed in workshops or dormitories above the second floor. Even if they must be installed, they must be able to be opened from the inside; 7. Offices, warehouses, dormitories, canteens, flammable and explosive workshops, etc. need to install smoke alarms; 8. All fire-fighting equipment, facilities, passages, exits, etc. need to be inspected daily, and inspection records must be kept; 9. A fire drill must be held every 6 months, and all personnel must participate. If there are several factories in the factory area, a joint fire drill must be held and records must be kept; 10. Each floor and each workshop must be equipped with professionally trained firefighters, whose photos and names are posted in a conspicuous place in the workshop, and who are required to wear firefighter armbands for easy identification; 11. Emergency assembly points for fire evacuation must be marked within the factory area; 12. The fire protection acceptance report of the factory building must be obtained; 13. Escape and evacuation signs must lead to emergency evacuation assembly points; 14. Each corner of the emergency exit staircase must have a 24-hour light tube-type emergency exit sign and emergency light, as well as a fire evacuation map (the standing position must be required); 15. All new employees must complete fire safety training within 7 days; 16. Walmart listed electrical safety as a fire protection issue, such as the distribution box was not locked, had no inner cover, exposed wires, the power box switch was not marked with its purpose, and had no warning signs, etc. 17. Fire hydrants must be installed on each floor and have water and complete accessories; 18. Chemicals must be kept away from open flame work areas or fire sources; 19. Setting of escape signs: Set escape arrows with fluorescent signs on the floor, at least one every 20 meters and one per meter at the corners. The live light signs must be installed below 1 meter. 20. There are sufficient fire extinguishers, one for every 80 square meters, the distance between two locations is no more than 23 meters, and the height is no more than 1.5 meters. There is an annual inspection by a third party, but no inspection by our factory personnel. |
<<: What problems will lead to a red result during the factory inspection?
>>: Sears factory audit results classification
eBay official website: https://www.ebay.com/ 1. W...
What is the RoHS Directive? On January 27, 2003, ...
In March 2007, LightInTheBox was officially launc...
Customer introduction: Shaoxing ** Knitting Indus...
Problem phenomenon: The pulley of the stamping ma...
eBay overseas warehouse access rules and regulati...
Japan Sitong Transshipment has set up a warehouse...
When searching for a product, when will the scree...
Let’s talk about ISO9001 first: ISO9001 is one of ...
There are always eBay sellers who say they haven&...
Global Sources has been building a trusted B2B pl...
What is Techbargains? TechBargains is one of the ...
In addition to BSCI's over-reliance on social...
Compared with other cross-border e-commerce platf...
LINE is an instant messaging software launched by...